2XD SERIES 240V > 480V
Phase-Converting Voltage-Doubling VFD
2XD205R
Designed specifically for deep pumping applications. Both phase-converting and voltage-doubling VFD for a single 5HP motor load.
Description
Summary
Phase Technologies has designed a simple, phase converting, voltage doubling solution for residential and light commercial constant pressure installations (5-7.5 hp). The 2XD product line offer simple setup, rugged hardware, 3R cabinets, and a top-of-the-line oil filled pressure transducer standard with every package.
If you’ve installed submersible pumps, you know motor cable is a costly expense. Voltage doubling, developed exclusively by Phase Technologies, “doubles” the voltage from 240V to 480V. In turn, it requires smaller gauge motor cable. This saves significant cost on pump and drive installations, especially in deep wells. The 2XD series also integrates and optional sine filter that is less expensive than a dv/dt filter making this the obvious choice for deep submersible installations.
Demand-driven constant pressure for home wells is now inexpensive, reliable, and a luxury available to all homeowners thanks to Perfect Pressure, standard with all SD and 2XD systems. Perfect Pressure only requires a few minutes of setup time and can control the most complicated plumbing systems with ease. With constant pressure, plumbing systems run smoothly with fewer instances of short cycling.
Target Market
Industries served, Wells Pumps, Irrigation Pumps, Motor Control
Standard Features
- NEMA 3R Enclosure w/Insect Guards
- Easy Perfect Pressure™ Setup
- Strikesorb Surge Protection
- 2-Year Warranty
- 122° F (50° C) Rated
- Easy Field Serviceability
- Includes 0 - 150 psi transducer
Specifications
Models: | 2XD205R | 2XD207R | 2XD210R | 2XD215R |
General Power Specs | ||||
Rated HP | 5 HP | 7.5 HP | 10 HP | 15 HP |
Rated Input Current | 31A | 52A | 64A | 87A |
Input Voltage | 240V, single-phase | |||
Rated Output Current | 10A | 13A | 18A | 24A |
Output Voltage | 480V, three-phase | |||
Other Specs | ||||
Recommended Breaker Size | 40A | 60A | 80A | 100A |
Min Wire Size | N/A | N/A | N/A | N/A |
Enclosure size (H x W x D) | 29 x 16 x 12" | 29 x 16 x 12" | 29 x 16 x 12" | 29 x 16 x 12" |
Shipping Weight | 70 lbs | 80 lbs | 85 lbs | N/A lbs |
Shipping Type | Ground | Ground | Ground | Ground |